Victron MultiPlus Compact 24v 12v 800w to 2000w:
Inverting power from DC to AC power. The Victron MultiPlus Compact range comprises models with constant outputs rated as follows
The main output has no break functionality. The MultiPlus Compact takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus Compact. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus Compact is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus Compact will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus Compact will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure.
Loss of mains detection software is available.
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar Chargers